PRODUCTS Picoammeter CP10A
»Cable Leakage Tester CE1012
»Charge Amplifier CA10
»Charge Amplifier CA6/C
»Charge Amplifier CA7/C
»Current to Frequency Amplifier CEI2F
»Double Pulse Generator DLP8
»Floating EHT Supply Unit 1010
»Gamma Radiation Monitor CGM5
»Geiger Counter CEG4
»Half Life Demonstration Unit CP3-IC
»HV Power Supplies
»Interference Test Set, 95/4201-3/4
»Log Amplifier AVF913
»Low Noise EHT Supplies - LN310
»Low Noise EHT Supply - LN225
»Low Noise EHT Supply LN26
»Noise Analyser NA4
»Nucleonic Pulse Counting System
»Picoammeter CP10A
»Picoammeter CP13
»Picoammeter CP8
»Portable 5kW Pulse Generator
»Power Supply Unit Type SU3/C
»Power Supply Units, Types SU1/C & SU2/C
»Pulse Counter Pre-Amplifier CPA60
»Pulse Generators DLP5 & DLP7
»Pulse ZT Test Set Type 95/4232-2/4
»Radiation Monitor CGM8
»Radiation Monitor Head Unit CRM15
»Radioactivity Detector CGM7
»Reactor Pulse Generator RPG9
»Voltage Ramp Generator CRG3
»Wide Band Amplifier WB 15-44
»Wide Band Amplifier WB 15-54
Picoammeter CP10A - Cooknell Electronics Ltd Standard Electronic Products Manufacturered in Weymouth, Dorset
ENLARGE IMAGE
The picoammeter CP10A is a mains powered instrument for measuring DC currents with 10 full scale ranges of 1.0 x10-3A to 1.0 x10-12A.

The front panel LCD has a full scale reading of 10.00 and a rear panel socket provides access to a voltage proportional to input current. A front panel control enables the output to be offset by ±100mV to facilitate driving unipolar voltage to frequency converters. A rear panel mounted 'D' socket provides indication of range, status and power for a remote indicator. A front panel switched output smoothing control provides risetimes of 100µs to 300ms in 8 positions with a 1, 3, 10 sequence. The backlit LCD brilliance is front panel adjustable. An audible warning is given when the input signal exceeds the selected range full scale by 20%.

Specifications:

At 20°C after 10 minutes settling period and output offset nulled.

Range DPM Error O/P Error Temp. Co. Typ. Stability
(A FSD) (%) (%) (ppm/°C) (% Per Year)
10x10-4 1.5 1 ±50 ±0.1
10x10-5 1.5 1 ±60 ±0.1
10x10-6 1.5 1 ±50 ±0.1
10x10-7 1.5 1 ±60 ±0.1
10x10-8 2.5 2 ±150 ±0.2
10x10-9 2.5 2 ±160 ±0.2
10x10-10 2.5 2 ±150 ±0.2
10x10-11 2.5 2 ±160 ±0.2
10x10-12 3.5 * 3 * -1000 typ ±0.5
10x10-13 3.5 * 3 * -1000 typ ±0.5
* Plus residual current of 2x10-14A max.

Initial Input Offset <20uV
Input Offset With Temp. ±10uV/°C
Input Offset With Time ±50uV per year
Input Offset With Signal 10uV
Output Risetime 100us to 300ms switchable
Input Connector BNC on front panel
Analogue Output BNC on rear panel
Output Impedance 50 ohms
Output Scaling ±10V for ±FSD on selected range
Digital Outputs 9 way 'D' on rear panel
TTL level Range indication (4 lines)
TTL level Supply On indication (1 line)
TTL level Over-range indication (1 line)
24V dc supply output for remote indications
Overload Withstand 100V dc or rms ac on 10x10-4 and 10x10-5A ranges
250V dc or rms ac on all other ranges
Mains Connector IEC
Mains Supply 230V or 115V (switchable), 48 to 440Hz, 15VA max
Weight 2.5kg
Dimensions 210 x 120 x 220mm deep (free standing version)

This instrument is also available half width 3U rack mounting. The input connector can be provided on the rear panel as an option.

A remote indicator unit with DPM and range and status indications is also available.

Make an Enquiry about the Picoammeter CP10A