Cooknell Electronics Limited
ABOUTNEWSCONTACT USPRODUCTSELECTRONICSOPTRONICSCOMPUTERSSURPLUS STOCK
PRODUCTS Nucleonic Pulse Counting System
»Cable Leakage Tester CE1012
»Charge Amplifier CA10
»Charge Amplifier CA6/C
»Charge Amplifier CA7/C
»Current to Frequency Amplifier CEI2F
»Double Pulse Generator DLP8
»Floating EHT Supply Unit 1010
»Gamma Radiation Monitor CGM5
»Geiger Counter CEG4
»Half Life Demonstration Unit CP3-IC
»HV Power Supplies
»Interference Test Set, 95/4201-3/4
»Log Amplifier AVF913
»Low Noise EHT Supplies - LN310
»Low Noise EHT Supply - LN225
»Low Noise EHT Supply LN26
»Noise Analyser NA4
»Nucleonic Pulse Counting System
»Picoammeter CP10A
»Picoammeter CP13
»Picoammeter CP8
»Portable 5kW Pulse Generator
»Power Supply Unit Type SU3/C
»Power Supply Units, Types SU1/C & SU2/C
»Pulse Counter Pre-Amplifier CPA60
»Pulse Generators DLP5 & DLP7
»Pulse ZT Test Set Type 95/4232-2/4
»Radiation Monitor CGM8
»Radiation Monitor Head Unit CRM15
»Radioactivity Detector CGM7
»Reactor Pulse Generator RPG9
»Voltage Ramp Generator CRG3
»Wide Band Amplifier WB 15-44
»Wide Band Amplifier WB 15-54
Nucleonic Pulse Counting System - Cooknell Electronics Ltd Standard Electronic Products Manufacturered in Weymouth, Dorset
ENLARGE IMAGE
The General Purpose Pulse Counting System is a self-contained instrument requiring only a mains supply and an external detector for operation. It is intended primarily for use in the nuclear industry where randomly occurring low amplitude pulses are counted. It is suitable for use with fission chambers and BF3 and 3He detectors.

The instrument is housed in a 5U high, 19" rack mounting chassis. It is of modular in construction, being comprised of modules selected for particular customer requirements but typically includes: A Polarising Supply, Head Amplifier, Main Amplifier, Amplitude Discriminator, Scaler and Ratemeter.

Trips and Alarms can be incorporated and the Head Amplifier can be removed for remote operation.

EHT Unit PC/EHT1 Specifications:

The PC/EHT1 is a general purpose EHT unit with front panel switchable polarity whose output is variable by 10 turn potentiometer up to ±4kV. The output voltage is displayed by a 4 digit LED DVM. A facility is provided to rapidly discharge an external load.

Output Voltage (High) 400V to 4kV
Output Voltage (Low) 50V to 500V
Voltage Range Switch Locking toggle
Voltage Control Ten turn lockable
Output Current 0.5mA on 4kV range
Output Current 2.5mA on 500V range
Output Voltage Stability 100ppm/°C
Output Connector SHV

Head Amplifier PC/HA1 Specifications:

The Head Amplifier is designed to amplify the current pulses from BF3 and Fission counters. It was specifically designed to be used with Cooknell Electronics General Purpose Counting System where it can be housed within the parent instrumentation or removed remotely to reduce the cable length between head and detector. However, because of its excellent interference immunity and breakdown protected input it can beneficially be used as an update for existing installed instrumentation systems. The signal input impedance is variable via a control on the main amplifier to accommodate different cable types. A 50 ohm test input is provided on the Head Amplifier to allow testing without disconnecting the detector. A 50 ohm monitor output is also provided for connection to an oscilloscope.

Input Connector HN
Input Impedance 33 to 75 ohms
Signal Input Protection 4kV
Gain 2x104V/A ±10% into 50 ohms
Gain Temp-Co 200ppm/°C
Rise Time 8ns typ, 12ns max
Decay Time Constant >3ms with current input
EHT Input Connector SHV
Max EHT Voltage ±4kV
Test Pulse Input BNC
Test Input Impedance 50 ohms
Test Input Gain -14dB typ
Main Output Connector TNC
Main Output Impedance 50 ohms
Maximum Output ±2.5V into 50 ohms
Monitor Output Connector BNC
Monitor Output Impedance 50 ohms
Monitor Output Gain As main output
Maximum Output ±0.3V into 50 ohms

Main Amplifier PC/MA1 Specifications:

The Main Amplifier is a switched gain switched bandpass design housed in a well screened enclosure. Control lines interconnecting the front panel mechanical switches and the internal solid state signal switches are well filtered on entering the enclosure to ensure interference immunity. The output signal can be inverted and a monitor socket provides a buffered output to aid diagnostics. A front panel Head Supplies socket is available to power a head amplifier and controls are provided to set the input impedance of head amplifier type PC/HA1.

Input Connector TNC
Input Impedance 50 ohms
Gain 16dB to 69.5dB
Temperature Coef of Gain 200 ppm/°C max
Attenuator Coarse 0 to 48dB in 6dB steps
Attenuator Fine 0 to 5.5dB in 0.5dB steps
Time Constants 25, 50, 100, 200, 500 & 1500ns equal integrate and differentiate
Main Output Amplitude ±1.5V min into 100ohms
Monitor Output Impedance 50 ohms
Monitor Output Scaling Main Output / 10
Monitor Output Amplitude ±0.15V min into 50 ohms

Amplitude Discriminator PC/DSC1 Specifications:

The Amplitude Discriminator compares an input signal with a positive settable bias voltage. The bias voltage is set on a lockable ten-turn control. When the input voltage passes through the bias voltage level this event produces a TTL compatible output pulse. A switchable Dead Time circuit ensures that another output pulse cannot be generated within the preset time. The bias voltage is displayed on a 3½ digit DPM.

Input Impedance 100 ohms
Discriminator Level 0.1 to 1.1V
Discriminator Stability 150uV/°C
Dead Time 50ns, 100ns, 300ns, 1us, 3us & 10us
Monitor Connector BNC
Monitor Output >1V into 50 ohms
Main Output TTL

Scaler PC/SC1 Specifications:

The PC/SC1 scaler employs an 8 digit LED readout counter with manual Start / Stop controls together with a crystal controlled timebase to enable counting with gate times of 1, 10, 100, 1000 seconds and manual mode. An LED indicates when the gate is open and a second LED indicates an overflow condition. An audible 'tick' is available with the arrival of each pulse and a longer 'bleep' can sound the end of the selected counting period. A jack socket is available to drive a remote audio transducer.

Input TTL from Discriminator
Counting Resolution 50ns
Gate Time 1, 10, 100 & 1000s
Timebase Accuracy 300ppm ±50ppm/°C
Ext. Speaker 3.5mm jack, 40-200 ohms

Ratemeter PC/RM1 Specifications:

The PC/RM1 linear ratemeter provides a horizontal moving coil edgemeter display of input PRF. Its full scale sensitivity is switchable in a 1, 2.5, 10 sequence from 1 to 104 pps and the meter can be damped with a switch selectable smoothing control with time constants from 0.2 to 125 seconds. A reset push button enables the smoothing circuit to be rapidly discharged. A front panel DC output is available for an external meter/recorder. Overload input count rates in excess of 2x107 will result in a beyond FSD reading.

Input TTL from Discriminator
Ranges 1pps to 104pps
Output Connector BNC
Output Amplitude -10V FSD

Make an Enquiry about the Nucleonic Pulse Counting System
Name:
Email:
Enquiry:
Tel: 01305 773744 | Fax: Not Available | Email: qa@cooknell-electronics.co.uk